City of West Fargo

Request for Proposals Dual West Fargo Fueling Stations

Solicitation: Not available
Notice ID: 2c2da1384114f22042e269740f7d4add
Contract snapshot

Federal opportunity from City of West Fargo. Place of performance: ND.

Source
Open on official portal →
Solicitation
2c2da1384114f22042e269740f7d4add
Performance
West Fargo, ND
Response
No due date posted
Open on official portal →
Map for ND
Live POP
Place of performance
West Fargo, ND
State: ND
Contracting office
Not listed

Point of Contact

Not available

Agency & Office

Department
City of West Fargo
Agency
Not available
Subagency
Not available
Office
Purchasing
Contracting Office Address
Not available

Applicable wage determinations

Best public WD match for the notice location and scope.

Directory →
Best fitDavis-Baconstate match • county match
ND20260050 (Rev 2)
Published May 18, 2026North Dakota • Cass
18 occupation rates available in the full WD.
View more WD detail
3 more WD matches and 16 more rate previews.
Davis-BaconBest fitstate match • county match
ND20260050 (Rev 2)
Open WD
Published May 18, 2026North Dakota • Cass
Rate
ELECTRICIAN
Base $44.98Fringe $18.38
Rate
POWER EQUIPMENT OPERATOR: BULLDOZER
Base $35.00Fringe $22.45
Rate
POWER EQUIPMENT OPERATOR: FORKLIFT
Base $34.85Fringe $22.45
+15 more occupation rates in this WD
Davis-Baconstate match • county match
ND20260001 (Rev 2)
Open WD
Published May 18, 2026North Dakota • Adams, Barnes, Benson +50
Rate
N, BURKE, DIVIDE, DUNN, EMMONS, GOLDEN VALLEY, GRANT, HETTINGER, MCHENRY, MCKENZIE, MCLEAN, MERCER, MOUNTRIAL, OLIVER, PIERCE, RENVILLE, ROLLETTE, SHERIDAN, SOIUX, SLOPE, WARD, & WILLIAMS COUNTIES
Base $55.35Fringe $24.55
Rate
LINE CONSTRUCTION: LINEMAN
Base $55.35Fringe $24.55
Rate
LINE CONSTRUCTION: LINE EQUIPMENT OPERATOR
Base $47.00Fringe $22.21
+20 more occupation rates in this WD
Davis-Baconstate match • county match
ND20260013 (Rev 2)
Open WD
Published May 18, 2026North Dakota • Cass
Rate
BOILERMAKER
Base $48.00Fringe $31.14
Rate
BRICKLAYER
Base $33.54Fringe $14.86
Rate
ELECTRICIAN (EXCLUDES LOW VOLTAGE WIRING)
Base $37.41Fringe $18.62
+21 more occupation rates in this WD
Davis-Baconstate match
ND20260040 (Rev 2)
Open WD
Published May 18, 2026North Dakota • Mercer
Rate
CARPENTER
Base $35.87Fringe $25.10
Rate
ELECTRICIAN
Base $44.98Fringe $18.38
Rate
POWER EQUIPMENT OPERATOR: BULLDOZER
Base $35.00Fringe $22.45
+11 more occupation rates in this WD

Description

Bid Postings • Request for Proposals Dual West Fargo Fueling Skip to Main Content Create a Website Account - Manage notification subscriptions, save form progress and more. Website Sign In City Government & Departments Resident Services Business & Development About West Fargo Fire Police Library Public Works Economic Development /QuickLinks.aspx Search Home Bid Postings Print Sign up to receive a text message or email when new bids are added! Print Bid Title: Request for Proposals Dual West Fargo Fueling Stations Category: City of West Fargo RFP Status: Closed Description: *03/20/20204 - ADDENDUM DOCUMENT ADDED - SCROLL TO DOWNLOAD* INTRODUCTION Section 1.01 Introduction. The West Fargo Public Works Department (the “Public Works Department”) within the City of West Fargo, North Dakota (the “City”) is soliciting proposals from vendors for Dual Fueling Stations in the City (the “Project”). Each respondent shall submit a proposal (each a “Proposer”). Sealed proposals will be received by the Public Works Department at 810 12 th Ave NW, West Fargo ND, 58078. Proposals will be received until [2 Pm] Central Standard Time on [March 20 th , 2024]. Upon completion of an evaluation by the Selection Committee and approval by the City Commission, a contract may be signed. Must be clearly marked (Dual Fueling Station). Section 1.02 City Rights. The City reserves the right to cancel this RFP in writing or postpone the date and time for submitting proposals at any time prior to the due date. The City, by this RFP, does not promise to accept the lowest cost or any other proposal and specifically reserves the right to reject any or all proposals, to waive any formal proposal requirements, to investigate the qualifications and experience of any Proposer, to reject any provisions in any proposal, to modify RFP contents, to obtain new proposals, to negotiate the requested services and contract terms with any Proposer, or to proceed to do the work otherwise. Furthermore, the City reserves the right to award subsequent work to the consultant selected for this Project without going through an additional request for proposals process. The City hereby notifies all proposers that it will affirmatively insure that in regard to any contract entered into, pursuant to this request, minority business enterprises will be afforded full opportunity and are encouraged to submit proposals in response to this invitation and will not be discriminated against on the grounds of race, color, sex, or national origin in consideration for an award. The City reserves the right to accept or reject any and all proposals that are in the best interest of the City. Questions or requests for clarification regarding this RFP should be submitted via email, citing the RFP page and section, by the question deadline. Questions will not be accepted orally, and any question received after the deadline may not be answered. All questions and inquiries will be addressed to: Brian Matzke, Operations Manager Matthew Andvik, Director Public Works Department Public Works Department Section 1.03 Successful Proposer. After the opening and completion of a review process to determine each Proposer’s responsibility and responsiveness, and satisfaction of qualifications, the City proposes to enter into a contract to design, solicit bids, and administer contracts for the Project. Proposers are encouraged to provide sufficient detail in their proposal in order to allow the City to fully review and understand the terms and conditions of such proposals. ARTICLE II. OVERVIEW AND BACKGROUND Section 2.01 Focus. The focus of this RFP is for the City to add two (2) commercial fueling stations with fuel pumps, fuel controls, and a fuel management system. It is intended that the addition of two (2) commercial fueling stations will help the City run proficiently and more cost effectively. The City is in the process of considering different layouts, equipment options, and software related to the Project. The purpose of this RFP is to identify the most qualified contractor capable of delivering the Scope of Services defined herein. Section 2.02 Location. The City is located in Cass County, North Dakota, with an estimated population of 39,985 people. The City currently utilizes public fuel stations located in different locations in the City which hinders performance and budget. One (1) fueling station will be located on the northwestern side of the City, as shown on attached Exhibit A . The address of the site is 810 12 th Avenue North West, West Fargo, North Dakota 58078, and sits on a parcel of land owned by the City (“Site 1”). The second fueling station will be located in the western side of the City, near the intersection of 40 th Avenue West and 170 th Avenue South East, as shown on attached Exhibit B . The address of the second site is 4015 4 th Street West, West Fargo, North Dakota 58078, and sits on a parcel of land owned by the City (“Site 2”). Section 2.03 Project Objectives. The Project objectives include: i) Site 1 – provide a turn key operation fueling station with canopy; and ii) Site 2 – provide a turn key operation fueling station without a canopy. Project objectives are described in further detail in Article III. Scope of Services. ARTICLE III. SCOPE OF SERVICES Section 3.01 Generally. Interested Proposers shall submit a proposal as further instructed below and based on the following anticipated Scope of Services. Proposers are also encouraged to suggest additional scope items and recategorize scope items, as deemed necessary, to ensure the Project is successful. Proposers shall clearly document their proposed approach for carrying out each task. Section 3.02 Site 1 – Turn Key Fueling Station With Canopy. Requirements: The successful Proposer shall work with the City on layout and placement with regard to the Project at Site 1. Proposer is responsible for providing the following items for a turn key fueling station with canopy: Excavate out a hole to house two (2) New Ellutron double walled underground tanks. One will be a twelve thousand (12,000) gallon for gas, and one will be twelve thousand (12,000) gallon for diesel. The tanks will be held down with dead man anchors. Tanks will be placed in washed pea rock all the way around the tanks and back up to final grade. Set primed carbon steel island with 48” x 48” x 18” tall triangle bollard ends and also include the fiberglass dispenser sumps, where the new Gasboy Atlas X Electronic 1GR/2SI/2HO 20 Gpm for gasoline dispensers. Set primed carbon steel island with 48” x 48” x 18” tall triangle bollard ends and also include the fiberglass dispenser sumps, where the new Gasboy Atlas X Electronic 1GR/2SI/2HO 20 Gpm for diesel dispensers. For activating the dispensers, provide an Islander Prime Fuel Management System and include 600 Mifare Tags. Supply 2HP Variable Speed submersibles in each tank with a fiberglass tank sump around the submersibles, and supply 1-1/2 APT double walled underground piping from the tank sump to the dispenser sumps to make system totally contained. Tank monitoring must include a new TLS 450 Plus with the Pressure line leak detectors, and adding new sump sensors for the tank sumps and dispenser sumps and new interstitial sensors in each tank, and a Tank Probe in each tank, along with an overfill alarm. For spill prevention, must include the double walled below grade spill containers with the overfill shut down. Include Stage 1 Vapor Recovery on the gas product. Provide column canopy with Bronze color under decking, 36” white fascia, and 16 Sloan LED Canopy Lights for over the island area. Furnish all equipment and services for one (1) year to make station fully operational. Special notes for this specific equipment: 2 - 12,000-gallon double walled Ellutron Underground tank (9’x 25’) Strap, tiedown, tank, 16L, 108” dia 2 - Gasboy Atlas X 1Gr/2Si/2Ho Electronic Fleet 20gpm dispenser for gas 2 - Gasboy Atlas X 1Gr/2Si/2Ho Electronic Fleet 20gpm dispenser for diesel Valve, Shear, 1.5” Mnpt, Double-pop Assembly, Complete, Cat-Tail, Gas ¾”, All Hose, Noz Swiv, Breakaway Ekos Cloud One Time Setup Fee (Ekos-Startup) Enterprise Software MiFare Tag reader Ekos Fuel card module Islander prime fuel Management system Islander prime standard pedestal base Mifare Tag reader Gasboy service offering 600 Mifare tags Console, Tank, Mon, Tls-450, Plus W/Prin and 7.4” Lcd, W/Software Module, Universal, Sensor/Probe Interface Module Universal, Input/output Interface Sensor, Turbine, Sump, Single float Sensor 4’-12’ Interstitial liquid Software, Dplld, Module Risk Management Tls450 Probe, 9’ Hgp, Stainless Steel Mag Plus, Water Detection Alarm, External, Overfill Switch, Remote, Acknowledgement for Overfill Alarm Pump, Submersible, 2Hp, Varispeed Magshell, Ap, 90”-151” 10” riser Magvfc, 2Hp controller, One per Stpm, Vs2 or Vs4 Valve, Ball, Full-port, Brass Spill-cont, 5 gal, Bg, Sw, Defender Npt, White, No drain (Vapor Recovery) Spill-cont, 5gal, Bg, Dw, Defender NPT, Blk, no drain Valve, Overfill, Defender Series 5’Top, 10’ Bottom Drop Tube/ (Testable) Extractor, 4” x 4” x 2”, W/Cage (On Vent Side) Sump Dispenser, SW, Fiberglass Gasboy Sign, Emergency Shut-off Switch Red/White, 12” W by 8” H, Aluminum Switch, Emer, Stop, Keyed w/N.O. and N.C. Contacts Extinguisher, Fire, 20#, 6A:80B:C, Kiddle, 466206 Cabinet 20# Fire Extinguisher Primed carbon steel islands 4’ x 24’ x 10” with 48” x 48” x 18” Tall Triangle Bollard ends Tfc 30’ x 56’ four column canopy w/embossed Bronze under decking and 36” White Fascia Hanging of 8 Led canopy lights, Bronze Textured Lens Snow load must be 50 psf. The wind load is 113 mph for canopy Vent pipe is to run up one of the canopy columns of the canopy Provide Electrical specs for equipment Concrete specs Must Have Local Service Department Apply for Fire Marshall Permits Excavation: Excavate out a hole and set in place two (2) twelve thousand (12,000) gallon double walled Ellutron underground tanks. Note

Advisory bid range

Pricing and bid posture

high confidence
$625,611 - $741,464

Contractor-side estimate from visible notice metadata, NAICS/PSC, contract type, schedule hints, and BidPulsar workpaper assumptions. Not an IGCE, incumbent price, award value, or government budget.

Calibrate full bid price →
Floor
$625,611
Target
$662,022
Premium
$741,464
Labor
$329,680
Direct
$32,000
Burden
$221,360
Fee + reserve
$78,022
Target $662,022Hybrid workpaper with explicit assumptions4 modeled rows

This advisory bid range is visible page text for contractors and search engines: it summarizes the modeled floor, target, and premium bid posture for this solicitation.

Market snapshot

Baseline awarded-market signal across all contracting (sample of 400 recent awards; refreshed periodically).

12-month awarded value
$3,515,334,796
Sector total $3,515,334,796 • Share 100.0%
Live
Median
$350,000
P10–P90
$32,216$3,347,126
Volatility
Volatile200%
Market composition
NAICS share of sector
A simple concentration signal, not a forecast.
100.0%
share
Momentum (last 3 vs prior 3 buckets)
+100%($3,515,334,796)
Deal sizing
$350,000 median
Use as a pricing centerline.
Live signal is computed from awarded notices already observed in the system.
Signals shown are descriptive of observed awards; not a forecast.

Files

Files size/type shown when available.

BidPulsar Analysis

A practical, capture-style breakdown of fit, requirements, risks, and next steps.

Analysis is being generated for this notice. Check back shortly.
Federal Bid Partners

Service match

Optional support routes matched to this notice after the core solicitation details.

Need help writing this bid?
Route this notice into proposal, compliance, and submission support without burying the solicitation record.
Open proposal plans

Related hubs & trends

Navigate the lattice: hubs for browsing, trends for pricing signals.